Key Features

WM-380P is an efficient and reliable automatic steam sterilizer. Specially designed for large capacity and highest flexibility in processing requirements. It can be used in a hospital for efficient, high-volume processing of heat and moisture stabile materials, such as fabrics, wrapped hard goods, liquid or glassware etc.

Features
1.Control system:automatic control system provides strict con trol of sterilize temperature,time,pressure etc to assure consistent,accurate performance.
2.Sterilizer cycles:there are 3 pre-programmed cycle selections that can process various load types in this sterilizer. For easy sterilizer operation:1 Unwrapped cycle;2 Wrapped cycle;3 Liquid cycle.
3.Automatic operation: cycle progresses automatically through pulses vacuum,
sterilizing,exhaust,vacuum drying and venting phases.
4.Temperature controller:sterilize temperature can be set from 121℃ to 132℃ on digital temperature controller. When setting temperature is achieved the process of sterilizing cycle will automatic operating.
5.Timer:sterilize time and dry timer can be set from 0~99 minutes on digital sterilizing timer and drying timer. The timer starts only after the pre-set temperature is reached,ensuring complete sterilization.
6.Status display: illuminated pilot lamps display status and a buzzer announces the completion and cuts off the heating power source.
7.Pressure gauge:the large diameter of chamber pressure gauge and jacket pressure gauge make ideal require reading and indicate high precision and consistent results.
8.Heating system:integral steam generator is equipped with a high efficient immersion heater and automatic feed water device to supply steam to sterilizer.
9.Vacuum system:controlled and monitored pulses vacuum and drying phase effectively condition loads of various size and density...reducing total sterilization time.  System includes a condenser and water ejector.
10.Steam trap:discharges condensate from chamber to obtain effective saturated steam.
11.Air filter:an effective HEPA air filter is used to prevent contaminated air from entering into the chamber.
12.Chamber door:chamber door is manually operated and actuated by rotating a door handle.
13.Gasket:the silicon-rubber sealing gasket is applied to an even pressure door handle.
14.Chamber shell:cylindrical chamber provides a large capacity to satisfy a wide range of sterile processing needs.

Safety devices
1. Safety door switch: cycle does not start unless chamber is locked also door-unlocked signal is displayed on the control panel.
2.Door interlock: door safety locking device keep door from being opened while chamber is pressurized during cycle.
3. Safety vale: releasing steam in case of excessive chamber pressure.
4. Overheating protection device: high temperature deviation in chamber actuates protective device cuts off the heating source immediately.
5. Low water protection device: low water level in steam generator will actuate audible alarm and protective device cut off the heating source immediately.
6. Circuit protection device: circuit breaker and fuse protects control units when short circuit of overload occurs.
7. Emergency exhaust: manual exhaust to vent the chamber and remove the load in the event of a power outage.

Norms and standards
Manufacturer correspond with quality system certified to GMP Taiwan.

Accessories
1. Bottom shelf x 1
2. Operation manual x 1

Specifications
 Model
Chamber Size
(mm) 
Volu
-me
(L) 
Door
Opera
-tion 
Tempera
-ture
Cont
-rol 
M.A.
-W.P
(kg/
cm2
Design Temper
-ature (
Maximum Working Temperature (Sterilizing & Drying Timer (mins) 
Electric power
(kw)

Steam Generator 
Electric power
(kw)

Central Steam  
 PowerChamber Material Jacket, Chamber Door
& Shell Material 
 WM-380p
 ψ450 x D950
ψ500 x D1000
ψ600 x D1000
ψ700 x D1200
151
196
283
462
 Manual Hinge DoorLED Digltal Temp
-erature Contr
-oller  
2.5 138 132 0~99 
12
12
18
24 
2.5 
220/380V
1PH/3PH
 50/60Hx
 Stainless
Steel

Stainless
Steel
 

Last Update : 2014-10-09
LoadingLoading ...


The purpose of Slider Kit is to gather common slideshow-like jQuery functionalities (such as news sliders, photos galleries/sliders, carousels, tabs menus)

When tracking mouse movement, you usually need to know the actual position of the mouse pointer. The event object that is passed to the handler contains some information about the mouse coordinates.

Step 1Fill in the formStep 2Completion

Mr.Mike Huang , ALREADY ENTERPRISE INC.

USD
Insert a template
0/1500

File formats: htm, html, doc, docx, pdf, txt, jpg, gif, png. Max 3 files (10MB in total).

Total size:0

  • +

This helps to more precisely match your inquiry with potential suppliers.Use "," or "enter" to separate multiple keywords.

Please fill in all required fields.

    Recommendations

    Loading ...

    Small Order Recommendation

    Loading ...